12KW Three-Phase Low-Voltage Inverter-Efficient and stable, designed for homes and businesses. Supports balanced three-phase output, seamlessly compatible with low-voltage batteries. Integrated smart energy management maximizes solar storage efficiency. IP65 rating and arc fault detection ensure safety-enabling greener, more economical and autonomous energy use.

.

HY12K-3PL-EU (12KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)
HY12K-3PL-EU (12KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)
Get Free Quote

Features of HY12K-3PL-EU (12KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)

  • 100% unbalanced output, max. output up to 50% rated for each phase

  • AC couple to retrofit existing solar system

  • On-grid and off-grid operation;

  • Support multiple batteries parallel

  • Max. charging/discharging current of 280A

  • 48V low voltage battery, transformer isolation design

  • 6 time periods for battery charging/discharging

  • Support storing energy from diesel generator




Specifications of HY12K-3PL-EU (12KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)

MODEL

HY12K-3PL-EU

Battery Input Data

Battery Type

Lead-acid or Lithium-ion

Battery Voltage Range (V)

40-60

Max. charge/discharge current(A)

250

Charging Strategy for Lead-Acid battery

3 stages curve

Charging Strategy for Li-ion Battery

Self-adaption to BMS

Number of Battery Input

1

PV String Input Data

Max. PV Access Power (W)

24000

Max. PV Input Power (W)

19200

Max. PV Input Voltage (V)

800

Start-up Voltage (V)

160

Rated PV Input Voltage (V)

360

MPPT Voltage Range (V)

200-700

Max. Operating PV Input Current (A)

30A + 30A

Max. Input Short-Circuit Current (A)

36A + 36A

No. of MPP Trackers/

No. of Strings MPP Tracker

2/2+2

AC Input/Output Data

Rated AC Input/Output Active Power (W)

12000

Max. AC Input/Output Apparent Power (VA)

13200

Rated AC Input/Output Current (A)

18.2/17.4

Max. AC Input/Output Current (A)

20/19.1

Max. Continuous AC Passthrough (grid to load) (A)

50

Peak Power (off-grid) (W)

2 times of rated power, 10s

Power Factor Adjustment Range

0.8 leading to 0.8 lagging

Rated Input/Output Voltage/Range (V)

220/380V, 230/400V 0.85Un-1.1Un

Rated Input/Output Grid Frequency/Range(Hz)

50/45-55, 60/55-65

Grid Connection Form

3L+N+PE

Total Current Harmonic Distortion THDi

<3% (of nominal power)

DC Injection Current

<0.5% In

Efficiency

Max. Efficiency

97.6%

Euro Efficiency

96.5%

MPPT Efficiency

>99%

Equipment Protection


Integrated

DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,

AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,

Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),

Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,

DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level

Surge Protection Level

TYPE II(DC), TYPE II(AC)

Interface

Communication Interface

RS485/CAN

Monitor Mode

GPRS/WIFI/Bluetooth/4G/LAN(optional)

General Data

Operating Temperature Range (℃)

-25 to +60℃, >45℃ Derating

Permissible Ambient Humidity

0-100%

Permissible Altitude

3000m

Noise (dB)

≤55

Ingress Protection(IP) Rating

IP 65

Inverter Topology

Non-Isolated

Over Voltage Category

OVC II(DC), OVC III(AC)

Cabinet Size (WxHxD mm)

422×658×254 (Excluding Connectors and Brackets)

Weight (kg)

45

Type of Cooling

Intelligent Air Cooling

Warranty

5 Years

Grid Regulation

IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,

OVE-Richtlinie R25, G99, VDE-AR-N 4105

Safety / EMC Standard

IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2



Applications Scenarios of HY12K-3PL-EU (12KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)

1. Power Core for Small Businesses and Farms

Scenario: Small supermarkets, farms, or workshops with three-phase motor equipment (e.g., water pumps, freezers, small machine tools) and rooftop solar panels.

Message: Perfectly adapts to low-voltage three-phase power environments, providing stable power for 380V equipment. Prioritizes solar energy to drive production equipment, significantly reducing operational electricity costs and increasing profit margins. This operational advantage is uniquely enabled by the intelligent management of a 3 phase solar hybrid inverter.

2. Balanced Power Supply for Multi-Story Villas

Scenario: Multi-story villas with high-power appliances (e.g., air conditioners, elevators, instant water heaters) distributed across phases, demanding extremely high power stability.

Message: Naturally aligns with three-phase grid connections in villas, effortlessly handling phase load fluctuations. Evenly injects solar energy into the three-phase grid, preventing trips caused by single-phase overloads and ensuring uninterrupted luxury living.

3. Safe Low-Voltage Energy Storage Solution for Older Community Retrofits

Scenario: Households with stringent safety requirements or communities with older grid infrastructure, where lower-voltage energy storage systems are more suitable.

Message: Seamlessly integrates with low-voltage energy storage batteries, offering inherently higher safety due to lower system voltage. An ideal and reliable choice for solar storage and backup power retrofits in older grid environments.

4. Key Node for Community Microgrids

Scenario: Schools, industrial parks, or small communities building local microgrids for shared and managed distributed energy.

Message: With inherent stability and high compatibility, it serves as an ideal node for microgrid construction. Easily parallelized to form larger-capacity three-phase power systems, promoting local consumption of green energy within the community.


Contact Hootrum for High-quality Solar Interver
Contact Hootrum for High-quality Solar Interver
X
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy
Reject All
Accept All