Shenzhen Hootrum Co.Ltd.
Shenzhen Hootrum Co.Ltd.
Contact Us

HY10K-3PL-EU (10KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)

Three Phase Hybrid Inverter

10KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery

Low Voltage inverter

Efficiency>98.6%


HY10K-3PL-EU (10KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)
HY10K-3PL-EU (10KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)
Get Free Quote

Specifications of HY10K-3PL-EU (10KW, 230/400Vac, 50Hz/60Hz, 40-60V Battery)

MODEL

HY10K-3PL-EU

Battery Input Data

Battery Type

Lead-acid or Lithium-ion

Battery Voltage Range (V)

40-60

Max. charge/discharge current(A)

220

Charging Strategy for Lead-Acid battery

3 stages curve

Charging Strategy for Li-ion Battery

Self-adaption to BMS

Number of Battery Input

1

PV String Input Data

Max. PV Access Power (W)

20000

Max. PV Input Power (W)

16000

Max. PV Input Voltage (V)

800

Start-up Voltage (V)

160

Rated PV Input Voltage (V)

360

MPPT Voltage Range (V)

200-700

Max. Operating PV Input Current (A)

30A + 30A

Max. Input Short-Circuit Current (A)

36A + 36A

No. of MPP Trackers/

No. of Strings MPP Tracker

2/2+2

AC Input/Output Data

Rated AC Input/Output Active Power (W)

10000

Max. AC Input/Output Apparent Power (VA)

11000

Rated AC Input/Output Current (A)

15.2/14.5

Max. AC Input/Output Current (A)

16.7/15.9

Max. Continuous AC Passthrough (grid to load) (A)

50

Peak Power (off-grid) (W)

2 times of rated power, 10s

Power Factor Adjustment Range

0.8 leading to 0.8 lagging

Rated Input/Output Voltage/Range (V)

220/380V, 230/400V 0.85Un-1.1Un

Rated Input/Output Grid Frequency/Range(Hz)

50/45-55, 60/55-65

Grid Connection Form

3L+N+PE

Total Current Harmonic Distortion THDi

<3% (of nominal power)

DC Injection Current

<0.5% In

Efficiency

Max. Efficiency

97.6%

Euro Efficiency

96.5%

MPPT Efficiency

>99%

Equipment Protection


Integrated

DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,

AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,

Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),

Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,

DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level

Surge Protection Level

TYPE II(DC), TYPE II(AC)

Interface

Communication Interface

RS485/CAN

Monitor Mode

GPRS/WIFI/Bluetooth/4G/LAN(optional)

General Data

Operating Temperature Range (℃)

-25 to +60℃, >45℃ Derating

Permissible Ambient Humidity

0-100%

Permissible Altitude

3000m

Noise (dB)

≤55

Ingress Protection(IP) Rating

IP 65

Inverter Topology

Non-Isolated

Over Voltage Category

OVC II(DC), OVC III(AC)

Cabinet Size (WxHxD mm)

422×658×254 (Excluding Connectors and Brackets)

Weight (kg)

45

Type of Cooling

Intelligent Air Cooling

Warranty

5 Years

Grid Regulation

IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,

OVE-Richtlinie R25, G99, VDE-AR-N 4105

Safety / EMC Standard

IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2