Features of HS1105EH48L Single Phase Hybrid Inverter
Reliable performance
Both the batteryside and the load side have super strong load
capacity,smooth voltage and current wavefomms, and can driveinductive loads such as air conditioning, supporting unlimited load
independent intelllgent load/generator interface, compatible withexisting PVsystem access, can operate without batteries (Pv*gridcombined power supply).
Even without a battery,it can be bypassed for output, importantloads willnot be powered off, The grid connected electricity salesfunction significantlyimproves energy utilization efficiency.
Economic benefits
2 MPPT channel, pVinput can exceed 1.7-2 times the rated power.supporting simultaneous full power charging and load,maximizingeconomic benefits.
Supports grid connected, off grid, and grid connected switching modes,with adaptive frequency and the ability to set charging and dischargingstrategies based on time of use electricity prices to achieve economicaenergy use.
Super Protection
AlCOT island protection, anti backflow (internal/external), PVreverseconnection alarm, External CT reverse connection alarm and opencircuit detection functions.
Friendly Design
High definition touch screen and LED screen are optional, supporting multiple languages; Removable dust cover suitable for harsh environments; Support battery activation function.
| Field | Value |
| MODEL | HS1105EH48L |
| Battery Voltage | 48Vdc |
| Battery Type | Lead-Acid Battery/Lithium Battery/Gel Battery |
| Output | |
| Rated Output Power | 10500VA/10500W |
| Rated Output Voltage | 220Vac/230Vac |
| Rated Output Frequency | 50Hz/60Hz ±5 Intelligent Adaptive/Setting |
| Output Waveform | Pure sine wave |
| Max Conversion Efficiency | 92.0% |
| Rated Current | 45.7A |
| Transfer Time | 10ms (typical value) |
| PV Input | |
| Max PV Input Power | 10000W+10000W |
| Max PV Input Current | 22A+22A |
| MPPT Voltage Range | 90~500Vdc |
| Max PV Input Voltage | 500Vdc |
| Max Charging Current (PV) | 200A |
| Number of MPPT / Strings per MPPT | 2/1+1 |
| Mains/ Generator Input | |
| Max Charging Current (Mains) | 120A |
| AC Input Voltage Range (UPS mode) | 170~280Vac, ±2% |
| Frequency Range | 50Hz/60Hz |
| Battery Input | |
| Battery Voltage Range | 40~60Vdc |
| Max Charging Current (Battery) | 200A |
| General Parameters | |
| Dimension (W*D*H) | 355*133*510 |
| Installation Method | Wall-mounted |
| Weight | 13.8 kg |
| Communication Mode | RS485/Dry contact control, Optional WIFI/4G |
| Protection Function | Grid Over/Under Voltage Protection, Grid Over/Under Frequency Protection, AC Output Short-Circuit / Overload Protection, High-Temp/Low-Temp Protection |
| Operating Environment | |
| Operating Ambient Temperature | -25℃~60℃ (>45℃ Derating) |
| Storage Ambient Temperature | -20℃~60℃ |
| Humidity | 0%~95% Non-condensation |
| Altitude | <2000m |
| Installation Environment | For indoor use only |
| Certifications | |
| Certification | CE, RoHS |
| Certification Standard | IEC/EN 61000-6-1/3, EN62920, CLASS B, IEC 62109-1, IEC 62109-2, IEC 62321 |